Lead in drinking water: pipes, filters, flushing and the rule
EPA says lead enters tap water when plumbing that contains lead corrodes. The steps that matter are finding out what you have, testing, and using a filter that is certified for lead.
By SavvyHearth Editorial Team Updated 7 min read
In short
EPA says lead gets into water when plumbing that contains lead corrodes, and that a lead service line is typically the largest source where one exists. Ask your utility or a licensed plumber what your service line is made of, get a test from a state-certified lab, and if you use a filter, choose one certified to reduce lead. The federal lead rule is in a transition: the action level is 15 ppb now, a final rule lowers it to 10 ppb on November 1, 2027, and a court challenge to that rule is pending. Questions about health belong with EPA, CDC and your doctor.
Where lead comes from
EPA's page on lead in drinking water, updated June 18, 2026, says lead enters water when plumbing that contains lead corrodes. Where a lead service line, the pipe from the water main to your home, is present, it is typically the largest source. Such lines are more common in older cities and in homes built before 1986. In a home without one, brass or chrome-plated brass faucets and lead solder are the most common problems. Water chemistry, contact time, temperature and pipe wear all affect how much lead gets into the water.
Lead cannot be seen, tasted or smelled, according to EPA. A test is the only reliable way to know, and the page says to use a certified lab from your state or local drinking water authority. The guide to testing your tap water covers how to find one and how to collect the sample.
Find out whether you have a lead service line
- Ask your water utility. EPA says to ask the utility or a licensed plumber what your service line is made of.
- Look for your utility's service line inventory. EPA's fact sheet says systems had to develop an initial inventory of service line materials and make it publicly accessible by October 16, 2024.
- Use EPA's "Protect Your Tap" guide, which EPA's page names as a way to check for lead pipes.
- Read your water quality report for lead sampling results and the utility's contact numbers.
Replacing a service line or plumbing is work for the utility and a licensed plumber, and part of the line is usually the utility's. Do not cut into the pipes yourself. Ask the utility who owns which part and whether it has a replacement program.
What flushing and other everyday steps do
EPA's page lists several steps for reducing exposure. It also says what they do not do.
- Flush the tap. Run the tap, take a shower or run laundry or dishes before drinking. EPA says the time needed depends on whether you have a lead service line and its length, and tells you to ask your utility for local recommendations.
- Use cold water. EPA says to use only cold water for drinking, cooking and baby formula.
- Clean the aerator. Lead particles can collect in the faucet aerator, so EPA says to clean it regularly.
- Boiling does not remove lead. EPA says so directly.
Flushing moves standing water out of the pipes. It does not remove the source, and it is not a substitute for a test or for replacing a lead line. Nearby construction can disturb lead service lines, according to EPA, which is a reason to ask your utility if work is planned on your street.
Filters certified for lead
EPA's consumer tool for identifying pitcher and point-of-use filters, dated June 2024, centers on NSF/ANSI 53. A filter that is certified for lead should show the certifier's mark, a statement that it was tested against NSF/ANSI 53 and a lead reduction claim to 5 ppb or less. Five accredited bodies certify these filters: NSF, IAPMO R&T, WQA, UL Solutions and CSA, and each has an online product directory. Reverse osmosis systems are covered by NSF/ANSI 58, so check the listing for a lead claim on that model as well.
| Where to look | What it should say | What it does not tell you |
|---|---|---|
| Package or filter | A certifier's mark and a statement of testing to NSF/ANSI 53 for lead | That the claim covers this exact model |
| Performance data sheet | The lead claim and the contaminants the filter was validated for | Anything it was not validated for |
| Certifier's directory | The model number listed as certified for lead reduction | Your own water's lead level |
EPA says to install and replace the filter according to its directions, not to run hot water through it, and warns that expired cartridges work less well. Certification is per contaminant and per model: a filter certified for chlorine taste may carry no lead claim at all. Compare cartridge cost per gallon with the pitcher and faucet filter guide and the water filter cost check.
Where the federal rule stands
The rule is the EPA Lead and Copper Rule Improvements (LCRI). EPA's LCRI page, last updated December 29, 2025, says the final rule requires systems to identify and replace lead pipes within 10 years. EPA's compliance-date fact sheet sets the main compliance date at November 1, 2027. These items are dated because they are changing.
| Item | What the source says | Status |
|---|---|---|
| Action level before November 1, 2027 | 0.015 mg/L, which is 15 ppb | In effect |
| Action level from November 1, 2027 | 0.010 mg/L, which is 10 ppb (EPA table of regulated contaminants, updated August 31, 2026) | Scheduled under the final rule |
| Lead pipe replacement | Systems must identify and replace lead pipes within 10 years | Final rule, challenged in court |
| Court challenge, AWWA v. EPA | Water utilities challenge the rule. EPA is defending it. NRDC's case page says briefing is complete and oral arguments were held on September 30, 2026 | Pending: no decision found |
The case page, last updated September 30, 2026, says a decision is likely six to twelve months after argument. That is NRDC's estimate, and NRDC is one of the groups defending the rule. Check EPA's LCRI page before relying on any date here.
Health questions go to EPA, CDC and your doctor
Questions people ask
Does boiling water remove lead?
No. EPA says boiling does not remove lead. Use a filter certified for lead, and follow EPA's advice to use cold water for drinking, cooking and baby formula.
Is the lead action level the same as a safe level?
No. EPA's action level is a trigger for further steps when more than 10 percent of tap samples exceed it, not a health limit for your home. EPA's health goal for lead in drinking water is zero.
When does the 10 ppb lead action level start?
EPA's table of regulated contaminants says systems must meet the revised 0.010 mg/L (10 ppb) action level from the compliance date of November 1, 2027. Until then, the 15 ppb level applies. A court challenge to the rule is pending.
How do I know a filter is certified for lead?
Look for a certifier's mark, a statement of testing to NSF/ANSI 53 and a lead reduction claim on the package or the performance data sheet, then confirm the model in the certifier's online directory.
Sources
- EPA: Basic information about lead in drinking water
- EPA: Lead and Copper Rule Improvements (page updated December 29, 2025)
- EPA: Final LCRI fact sheet on compliance dates
- EPA: Table of regulated drinking water contaminants
- EPA: Consumer tool for identifying point-of-use and pitcher filters certified to reduce lead (June 2024)
- NRDC: American Water Works Association v. EPA (Lead and Copper Rule Improvements)
Rules and pages checked on November 20, 2026. Pending: the LCRI action level of 10 ppb and the other final-rule dates (November 1, 2027) and the AWWA v. EPA challenge, for which no decision was found; the litigation status comes from the case page of NRDC, a party defending the rule, last updated September 30, 2026. Check EPA's LCRI page for the current status.
Read next
-
Water
Testing your tap water: kits and certified labs
Where EPA and CDC say to test, how to find a state-certified lab and how to take the sample.
-
Water
How to read your water quality report
What the yearly Consumer Confidence Report lists, and how to read MCLs, action levels and ppm, ppb and ppt.
-
Water
Pitcher and faucet-mount filters