Skip to content
SavvyHearth

NSF/ANSI 42, 53, 58 and 401: what each standard covers and how to check a claim

A standard is a list of tests. A certificate says one model passed particular tests for particular claims. The skill is reading which ones, and finding the model in the certifier's own listing.

By SavvyHearth Editorial Team Updated 7 min read

Illustration: a filter box with a certification mark beside a magnifier over a printed listing page

In short

NSF/ANSI 42 covers aesthetic effects such as taste and odor. NSF/ANSI 53 covers health effects. NSF/ANSI 58 covers reverse osmosis systems, and NSF/ANSI 401 covers emerging compounds and incidental contaminants. Certification is per model and per claim, so a filter certified for one thing is not certified for others. NSF, IAPMO R&T, WQA, UL Solutions and CSA all publish listings you can search. Use the listing and the performance data sheet, not the front of the box.

What each standard is about

The four standards in plain words
StandardCoversTypical claims
NSF/ANSI 42Aesthetic effectsChlorine taste and odor, particulates
NSF/ANSI 53Health effectsFor example lead, cysts, volatile organic chemicals (VOCs)
NSF/ANSI 58Reverse osmosis systemsTDS reduction is required; other claims are optional
NSF/ANSI 401Emerging compounds and incidental contaminantsListed by the claim on the certificate

The titles come from EPA's WaterSense guide, which lists 42 as aesthetic effects, 53 as health effects, 58 as reverse osmosis systems and 401 as emerging compounds and incidental contaminants. The same guide names NSF/ANSI 44 for softeners and IAPMO/ANSI Z601 for scale reduction devices; see whole-house filters and softeners. A standard written for health claims does not make every filter certified to it a health filter: each product holds the claims it was tested for.

Per contaminant, per model

NSF's page on label claims puts most weight on checking that the system has been tested and certified, then on whether the package or data sheet lists the contaminants it was verified for. It gives the example of a data plate that must say, for volatile organic chemicals, "Conforms to NSF/ANSI 53 for VOC reduction," and it sends you to the performance data sheet for each individual contaminant. NSF's page on NSF/ANSI 58 says the standard includes test procedures to verify various claims: TDS reduction is required, and claims for cysts, chromium, arsenic, nitrate and nitrite, lead and VOCs are optional.

  • A filter certified to 53 for lead is not, by that fact, certified for PFAS, and the reverse is also true.
  • The model is part of the certificate. NSF's page says the data plate should give the model designation for replacement components, so check that you are buying the cartridge the listing names.
  • Claims often carry limits. NSF's page says to look for usage limits on the package, such as forms of arsenic a system may not reduce.

Who certifies, and where to look a model up

EPA's June 2024 lead-filter guide names five ANSI-accredited third-party certifiers with product listing directories: NSF, IAPMO R&T, WQA, UL Solutions and CSA. EPA's WaterSense guide also lists ICC-ES among certifiers. Each certifier uses its own registered mark, which appears on the package, the filter or the smallest container, and the package text usually reads "Tested and Certified by" the certifier "against NSF/ANSI Standards 42 and 53," or names one of the two.

  1. Find the manufacturer, model number and standard printed on the package or data plate.
  2. Open the certifier's own listing: NSF, IAPMO R&T, WQA, UL Solutions or CSA. Use the one whose mark is on the box.
  3. On NSF's search, type at least three letters of the manufacturer or model, pick a product standard such as NSF 42, 53, 58 or 55, and optionally pick a reduction claim. The page says choosing several claims lists products certified for any of them unless you tick the box for all of them.
  4. Read the claims the listing shows for your exact model, and compare them with what your water report or lab result says you need.
  5. If the model is not listed, or the claim is not, call the manufacturer or write to the certifier. EPA's lead guide says to refer to the certifier's directory or contact the manufacturer.

EPA gives search instructions only for NSF's listing. For the other four, the listing pages are the starting point, so use the model number and the claim you need. The marks decoder shows what the certifier marks look like beside the other marks on a box.

Why "tested to" is not the same as certified

A maker can write that a product was "tested to" or "meets" a standard on its own. EPA says certification by an independent certifier helps ensure that the manufacturer's claims are independently verified and accurate. So the question to ask is whether the certifier lists the model, not whether the box names a standard. A claim that is not in the listing is the maker's claim, and you can treat it that way. Older shorthand such as P473 for PFOA and PFOS claims was replaced by claims under NSF/ANSI 53 and 58, so a current listing should name those standards.

What a certificate does not tell you

  • It does not say your water has the contaminant. Start with your water quality report or a state-certified lab.
  • It does not say the filter keeps working after its rated service cycle. NSF says the data sheet gives the rated cycle and that the filter needs changing after it; see filter upkeep and costs.
  • It does not rank brands or compare one certified model with another beyond the claims.
  • It does not make water safe to drink. It says a model did what its listed claims say in a test.

Questions people ask

What is the difference between NSF/ANSI 42 and 53?

NSF/ANSI 42 covers aesthetic effects such as taste and odor. NSF/ANSI 53 covers health effects. A filter can be certified for one, the other or both, and only for the claims on its listing.

Does NSF/ANSI 58 mean the system reduces everything in my water?

No. NSF says TDS reduction is a required claim under NSF/ANSI 58, and other claims, such as lead, arsenic or nitrate, are optional. Check the listing for your exact model.

Where can I check that a filter is really certified?

Search the certifier's listing: NSF, IAPMO R&T, WQA, UL Solutions or CSA, whichever mark is on the package. Search by manufacturer and model number, then read the claims shown for that model.

Is a filter certified by WQA or IAPMO as good as one certified by NSF?

EPA's lead guide names NSF, IAPMO R&T, WQA, UL Solutions and CSA as ANSI-accredited certifiers, each with its own listing. What matters is the standard and claim shown for your model, not which certifier's mark is on it.

Sources

Standards and listing pages checked on November 20, 2026. EPA's note that PFAS filter standards did not yet show removal to its new drinking water levels was dated April 2024 on a page last updated November 12, 2026, so check the certifier for current claims. The P473 history (replaced by claims under NSF/ANSI 53 and 58) was not re-opened for this page.